c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .
I have used the Froth-Pak 200 to air-seal rim joists--the area above the foundation wall in a basement. The first time I used it I did not shake the canisters well enough and the foam did not cure properly. Don't just shake the box for a few seconds. I take the tanks out of the box so I can shake/invert each tank for a minute or two. You will be able to hear the chemical sloshing around in the tanks. Also, don't ignore the recommended temperature for application--around 75 degrees F.

The problem you saw with the closed cell foam pulling away like that is due to the heat of the foam was to hot. It was actually curing out and making foam before it could adhere to the wood. The installer wasn't reading his foam correctly. He should of stopped and turned down the heat on his hose temp. Also installers have to be aware that as the sun rises and the temp in attics rises the subtrates get hotter as well. This will cause the installer to adjust his heat when installing the foam as the temp changes thru out the day.  

During colder months, 2 component foam is very sensitive to temperature variances. Per product instructions, both tank temperatures need to be above 70°F (21°C) for at least 24 hours prior to use. All application surfaces should be clean/dry and above 60°F (16°C) prior to application. Variance outside of the recommended temperature can affect foam yield and performance.

Roof Spray Foam Insulation

×