Spray foam comes in two flavors, open cell and closed cell, and provides both parts of the building envelope - the insulation and the air barrier. The building envelope should completely surround the conditioned space, and the insulation needs to be in contact with the air barrier. Since spray foam is both insulation and air barrier, proper alignment of insulation and air barrier is guaranteed.
Was hesitant to buy this product because of some of the reviews but glad I did. It does just what it says and we even got the square footage out of it. You just need to read ALL the directions first and it wouldn't hurt to read some of the helpful hints in some of the reviews. It does only cover 1 inch at 600 square feet and is extremely easy to apply. Very satisfied customer!

Spray foam is a fully adhered insulation that is spray applied into wall cavities, providing a continuous air and moisture barrier. Spray foam allows efficient use of your HVAC system and helps regulate the temperature fluctuations and humidity in your home. Spray foam effectively seals the building envelope, filling in any cracks and crevices, the common source of air and moisture infiltration as well as temperature variations.
The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.

Spray Foam Tanks


R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties. https://www.youtube.com/e/ggLAUsiuI_o
If you’re looking for an effective and efficient Elastomeric Roof Coating, you might want to consider the Kool Seal roof coating. This product comes in a 115 fl oz container and is white in color. It is easy to apply and use that it can stick well even in the harshest weather conditions. This product offers maximum clinging to the RV roof despite the temperature. You can also rely on its effectiveness no matter the type of weather.
a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer. https://www.youtube.com/watch?v=ggLAUsiuI_o
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.

Yes, a new roof should be coated if the building owner wants to add a highly reflective roof coating to reduce energy costs. The buyer should be aware of any warranties provided for a new roof that may violate that warranty during the period it is in force via the use of a roof coating. This will extend the roof’s service life. A reflective roof coating will reduce the heat load on the roofing assembly.
With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care.
I live in Baton Rouge LA with a very old and drafty house. There is no blockages in the walls between the crawl space and attic. Lots of critters just come on in. I would like to used closed cell sprayed under house to warm up floors and block moisture. I would like to spray closed cell into attic, but am afraid of enclosing attic due to moisture build-up. Can I spray closed cell against the attic floor in same way as installing bats, thus leaving my venting the same as it always has been. Other ideas? Thanks.
Porch urns are an excellent way to add seasonal curbside flair. However, tall items such as twigs, birch stems or even pumpkins can sway in the breeze and make a mess of your carefully planned decor. To prevent things from shifting, place your items in the container and spray around them with expanding foam to create a comfy nest that will keep your urns looking great. Place a layer of moss, hay or greenery on top to finish the look. http://youtube.com/watch?v=ggLAUsiuI_o
Having a recreational vehicle, see to it that you protect its roof from anything that would otherwise damage it or decrease its lifespan. One of the best maintenance and repair products you need is the best RV roof coating. It can offer you a host of benefits we’ve mentioned above, so it is really necessary for your RV cleaning and maintenance products arsenal. Pick based on those we’ve featured here as well as on certain factors, including your roof material, for the desired results. Did you like this guide? Share it on Facebook today! If you’re looking for more products in RV cleaning and maintenance, then I suggest going for these articles: best RV wash and wax, best RV roof sealants, best RV caulks, best RV wax, best RV roof cleaners and best RV awning cleaners. I do hope you will like them. Happy shopping!

We had issues with getting this foam to turn green in summertime in the South. We needed up spending an additional $300 on being able to spray this foam: 110 window a/c for shop & a $60 tarp to drape over the top, to keep the temps down. The areas where we had trouble-shooted were sticky & even after we wiped it down, the new green foam wouldn't stick. My husband had to apply Liquid Nails to it. For over $800, I expected alot more, plus the sellers customer service skills were in need of improvement.

If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

How Much For Spray Foam Insulation


JM Corbond® Open-Cell Appendix X Spray Foam is a lower-density, nonstructural foam that offers most of the thermal performance and installation benefits of closed-cell spray foam at a lower cost. It provides an exceptional air and sound barrier as well as R-value, and meets AC 377 NFPA 286 Appendix X requirements for application without an ignition barrier in attics and crawl spaces.

Porch urns are an excellent way to add seasonal curbside flair. However, tall items such as twigs, birch stems or even pumpkins can sway in the breeze and make a mess of your carefully planned decor. To prevent things from shifting, place your items in the container and spray around them with expanding foam to create a comfy nest that will keep your urns looking great. Place a layer of moss, hay or greenery on top to finish the look. http://youtube.com/watch?v=ggLAUsiuI_o
Part of that guidance will be explaining that interior, two component foam is applied with the professional using specific personal protective equipment (high-pressure foam is installed while using a respirator, for example). It is encouraged that professionals explain clearly to customers that this equipment, coupled with certain work and engineering practices, including ventilation, is used to minimize exposures to the chemicals used to make SPF during the job.
Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.

However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2] https://youtu.be/ggLAUsiuI_o
In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.
Another positive reason for using this elastomeric roof coating is its reflective nature against UV rays. In fact, it is known for reflecting over 90% of the UV rays. It is known for being one of those products that comply with environmental instructions that well. It has a sound-absorption feature, too, while being known to contract and expand together with your roof.
The complete line of JM open- and closed-cell spray foam insulation solutions provide superior thermal and energy performance, as well as advanced air, moisture and sound control in any climate. These products can be used in interior and exterior walls, unvented and vented attics, floors, ceilings and crawl spaces. Plus, using spray foam can reduce air leaks and create a more comfortable, energy-efficient home – meaning you could see more energy savings every month.
My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)
We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof?

While coatings may potentially stop minor leaks, the roof should be properly repaired and dried prior to coating application. Coatings may be able to seal pinhole leaks, which are leaks not visible to the naked eye. If the roof is leaking, the roof leak will need to be identified and repaired prior to any recoating; do not expect the coating to find and seal the leaks.

Spray Foam Basement Ceiling


I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.

How Much To Spray Foam Basement

×