Our commitment to using intelligent solutions and high-performing, quality products to help solve global environmental challenges is evident in both the use of renewable and recycled content in our products, as well as our green recognitions and certifications by various organizations, such as the NAHB Research Center, LEED Certifications, and USDA Bio-Preferred, just to name a few.
R-value is the term given to thermal resistance to heat flow. The higher the R-value of an insulation product, the more effective the insulation properties. Spray polyurethane foam comes in a range of densities and cel structure. Low density foams are referred to as Open Cel SPF while higher density foams are referred to as Closed Cel foam. 1.8-2 pound polyurethane foam has the highest R-value of readily available spray foam insulation used in homes and buildings.[4]
It also has a great waterproofing ability that can shield the roof’s membrane from water and moisture damage. You can also count on the liquid roof coating for its outstanding performance for a wide range of applications and uses. This product can be used at tears and seams as well as in sealing air conditioners and venting systems and anywhere else where rubberized coating is needed.
JM Corbond® Open-Cell Appendix X Spray Foam is a lower-density, nonstructural foam that offers most of the thermal performance and installation benefits of closed-cell spray foam at a lower cost. It provides an exceptional air and sound barrier as well as R-value, and meets AC 377 NFPA 286 Appendix X requirements for application without an ignition barrier in attics and crawl spaces.

Ames® Roof Coatings are premium elastomeric coatings that seal out moisture, renew old surfaces and even save energy. We have products specifically formulated for all types of roofs including; Wood, Tar, Metal, Rolled Roofing, EPDM Rubber, Foam and many other surfaces. Ames’ coatings form a waterproof seal to preserve and protect your roof. Our white roof coatings reflect sunlight, substantially reducing roof temperatures. Ames® products are environmentally friendly, waterbase, non-toxic, VOC-free and water cleanup. https://www.youtube.com/embed/ggLAUsiuI_o

To avoid the expense re-roofing a house that is simply suffering from nail fatigue, and to obtain optimum insulation, an 85mm layer of polyurethane foam can be sprayed onto the underside of the slates or tiles of a pitched roof. This stabilises and weatherproofs the roof by fixing the nails, battens and roofing felt. As the foam is a superior insulant, coupled with just 100mm of insulation at joist level, your roof will also meet the stringent thermal performance standards required for a new home. A typical roof can be insulated using the polyurethane treatment for around half the cost of re-roofing. http://www.youtube.com/e/ggLAUsiuI_o?app=desktop
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).
You can also take advantage of Heng’s rubber roof coating if you need to coat your RV’s rubber roof. It works well in sealing EPDM rubber roofs. It is also useful on seams and tears as well as in sealing vents and air conditioning units. This roof coating is a good choice if you are just in search of that with a 1-gallon capacity at the most reasonable price.
R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties.
This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.  

I used this product to seal and insulate my rim joists as I am finishing the basement. The builder used R13 batt insulation when we built the house 3 years ago. I use a dehumidifier to control moisture in the basement which is below grade. The setting I use is 55%. The dehumidifier kicks on periodically and requires emptying every few days. Since using the foam all around the house on the rim joists and sill plate, the dehumidifier has stayed at 50% for over two weeks since spraying and rarely turns on anymore. I also put the original R13 batt insulation back up after the foam cured.

Spray Foam Basement Walls Cost


Closed-cell spray insulation, a rigid medium-density material, can be used in exterior applications such as continuous insulation applications, as well as interior applications. This type of foam insulation has a higher R-value per inch making it also suitable for small areas that require the highest possible R-value to meet building code requirements. Closed-cell spray foam’s rigidity help reject bulk water making it a recognized flood-resistant material by FEMA.
I had a hole in the drywall in our bathroom that was about 2 in x 5 in that I used Great Stuff to fix. I am impressed with the characteristics of the filler. It filled the hole completely in a few seconds of application. I will warn anyone using it though to make sure you don't fill the hole entirely flush to the wall because this stuff continues expanding after you apply it. I didn't think about that but no big deal really because you can sand it which is exactly what I did, and then applied spacial and paint and it is almost as good as new. For the price this was a heck of a deal because I only used a tiny amount and now am left with nearly a full can. I guess I will have to find somewhere else to use it now. Great product, ... full review
While the function of spray foam insulation, to keep buildings warm during cold weather and cool during warm weather, is the same as traditional pink fiberglass insulation, that's where the similarities between the two materials end. Spray on insulation is, in fact, superior to fiberglass in a number of ways, which explains why it is rapidly becoming the insulator of choice for homes and business across the U.S. This buying guide explains the advantages of using spray foam insulation and provides general spray foam pricing.
This website uses cookies and other tracking technologies (also known as pixels or beacons) to aid your experience (such as viewing videos), as well as “performance cookies” to analyze your use of this website and to assist with marketing efforts. If you click the “Accept All Cookies” button or continue navigating the website, you agree to having those first and third-party cookies set on your device. If you do not wish to accept cookies from this website, you can choose to not allow cookies from this website by updating your browser preferences. For more information on how we use Cookies, please read our Privacy Policy. 

A. You can use closed-cell spray foam that way if you want, although you should realize that the spray foam will prevent the roof sheathing from drying inward. This approach should only be used if the roof sheathing is bone dry, because it will never dry when sandwiched in this manner. Most building scientists would prefer to see fiberglass rather than closed-cell spray foam under the roof sheathing in this type of assembly.
Spray foam comes in two flavors, open cell and closed cell, and provides both parts of the building envelope - the insulation and the air barrier. The building envelope should completely surround the conditioned space, and the insulation needs to be in contact with the air barrier. Since spray foam is both insulation and air barrier, proper alignment of insulation and air barrier is guaranteed. http://m.youtube.com/e/ggLAUsiuI_o
Closed-cell spray insulation, a rigid medium-density material, can be used in exterior applications such as continuous insulation applications, as well as interior applications. This type of foam insulation has a higher R-value per inch making it also suitable for small areas that require the highest possible R-value to meet building code requirements. Closed-cell spray foam’s rigidity help reject bulk water making it a recognized flood-resistant material by FEMA.

Spray Foam Roofing


I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response.  https://m.youtube.com/watch?v=ggLAUsiuI_o&feature=youtube_gdata
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock.
Loctite TITE FOAM Window and Door is a Loctite TITE FOAM Window and Door is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate around window and door jambs. Loctite TITE FOAM is a minimal-expanding foam based on purified and concentrated ingredients that provides four times more density versus conventional window and ...  More + Product Details Close
This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.   https://www.youtube.com/v/ggLAUsiuI_o&feature=youtube_gdata
Clean and free the roof surface of any debris and then dry the surface using a cloth. If you happen to have a current coating on the surface, check for adhesion. Consider removing loose coating, repairing, cleaning and then checking the area. Remember to use Energy Guard without thinning it because it is sold ready for use. Containers should not be left open except for a short period of time. You must also ensure that you check for any existing coating adhesion before opening Energy Guard. For application, you will require a brush preferably a bristle brush (synthetic) or a short nap roller. You can also use a good airless sprayer with a 0.031 or 0.027 tip to apply the coatings at (3000 psi/1gpm). You will also need water for cleaning up when you are done.

How Much To Charge For Spray Foam Insulation


Another thing we love about the Liquid Roof is its ability of not being damaged by freezing and other extreme temperatures. You will also appreciate its ability of staying flexible for a longer period of time. Did you know that it could also contract and expand as you roof moves? That is one of the things to look for when shopping around for this kind of product we found in the Liquid Roof.
The process by which heat energy in the form of light (usually IR unless the substrate is hot enough to glow in the visible range) is emitted more strongly by warm surfaces and absorbed by other materials especially those of low IR reflectivity (think matte black finish). Radiant heat transfer does not require a medium. Foam insulation materials, such as spray foam insulation, are opaque to thermal radiation, like most solid materials. http://m.youtu.be/ggLAUsiuI_o
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)

If you're chemically sensitive, it's probably not a good idea to get it installed, but it's also not a good idea to breathe musty air from the crawl space either. In addition, your house and its contents are made of lots of materials that affect your indoor air quality. If you're really concerned about this, hire a company to test your air and tell you what you can do about it.


The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.

How Much Is Spray Foam

×