When looking for a long-term roof solution, compare apples to apples. Liquid EPDM Rubber is a one-coat application. There are no primers needed, and when you begin adding up the cost of other systems that require primers and multiple coats, you are often exceeding the cost of liquid EPDM Rubber and have an inferior sealant on your roof. Why add unnecessary weight to a roof by using multiple-coat systems? Cut your time and labor costs in half with a one-coat system. Liquid EPDM has a very thick honey-like consistency and a slow cure time. One of the biggest benefits of the product. During the cure process, you will see bubbles resembling those created when you cook a pancake. This is the catalyst at work forcing the trapped air to the surface. What you have after the cure is a chemical bond between your roof and the coating. No other coatings produces this result. Other products trap this air making future cracks inevitable as temperatures change or expansion and contraction of the roof occur.
While coatings may potentially stop minor leaks, the roof should be properly repaired and dried prior to coating application. Coatings may be able to seal pinhole leaks, which are leaks not visible to the naked eye. If the roof is leaking, the roof leak will need to be identified and repaired prior to any recoating; do not expect the coating to find and seal the leaks.

Spray Foam Basement Ceiling


Spray foam is a very specialized packing material, often required for use in shipping valuable fragile items. Engineered packaging principles are designed to protect sculptures, vases, large fossils, lamp bases, busts, computers, furniture, chandeliers and other objects of unusual shape. By virtue of the liquid foam expanding by up to 30-60 times the volume of its liquid state, it efficiently protects almost any size, form and weight.
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.

Fill and seal expanding foam sealant is urethane Fill and seal expanding foam sealant is urethane foam designed to fill large areas quickly and permanently. Uses include filling holes cracks or gaps that require a complete airtight and waterproof seal but are too large to be filled with ordinary caulk. The foam expands approximately 3 times its original ...  More + Product Details Close http://www.youtube.com/watch?v=ggLAUsiuI_o&feature=kp
“It’s been scientifically proven that the temp of the shingles rises only a couple of degrees when there is an unvented attic compared to a vented attic,” said Garry Barlow, estimator at RetroFoam of Michigan. “If we lived in a southern state it has been proven that the longevity of the shingle did diminish by only one year. In the northern states there was no difference in the life span of the shingles.”
R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties. 

Spray Foam Insulation Near Me


In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.
Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
Apply coating when the roof is dry and the sealant has set. You will be using a 9-inch heavy-duty frame, ½-inch paint roller for spreading coating on roof or 1-1/4-inch roller for dipping in pail, and a 5–to-6-foot extension pole. Use a 3/4-inch roller with basecoats and emulsions. Map out your roof and make each pail fill that area. See Elastek Product Sheets for recommended coverage. An inexpensive 3-inch or 4-inch brush should be used to reach areas not possible with a roller. Use a stiff paintbrush for applying 103 Crack & Joint Sealant.
a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer. https://www.youtube.com/watch?v=ggLAUsiuI_o
We service the entire Central Texas Area including Waco, Abilene, Fort Worth, as well as Granbury, Aledo, Weatherford, Eastland, Hico, Hamilton, Brownwood, Comanche, Glen Rose, Meridian, Cleburne, Mineral Wells, Graham, Breckenridge, Decatur, Eastland, Ranger, Gorman. We have done work as far away as Colorado, so don't hesitate to call if you're outside this immediate area. https://www.youtube.com/v/ggLAUsiuI_o
To avoid the expense re-roofing a house that is simply suffering from nail fatigue, and to obtain optimum insulation, an 85mm layer of polyurethane foam can be sprayed onto the underside of the slates or tiles of a pitched roof. This stabilises and weatherproofs the roof by fixing the nails, battens and roofing felt. As the foam is a superior insulant, coupled with just 100mm of insulation at joist level, your roof will also meet the stringent thermal performance standards required for a new home. A typical roof can be insulated using the polyurethane treatment for around half the cost of re-roofing.

R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties. http://www.youtube.com/watch?feature=youtube.be&v=ggLAUsiuI_o


Stop making the same repairs using less reliable products that are not EPDM based, are not UV and ozone resistant, and do not have flexibility built into the material (causing them to crack). EPDM rubber will expand and contract with any surface as seasons change, and will not crack as a result of temperature changes. Other products will begin to bubble and crack in less than two years.
We had issues with getting this foam to turn green in summertime in the South. We needed up spending an additional $300 on being able to spray this foam: 110 window a/c for shop & a $60 tarp to drape over the top, to keep the temps down. The areas where we had trouble-shooted were sticky & even after we wiped it down, the new green foam wouldn't stick. My husband had to apply Liquid Nails to it. For over $800, I expected alot more, plus the sellers customer service skills were in need of improvement.
The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.

Spray Foam Tanks


Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.

I used this for the rim-joist in our home. A couple things: I put 1in solid core foam (cut to size) in each bay before using the spray foam. I also was able to do a relatively 'thick' spray to close off any potential gaps that may have existed. I turned off the HVAC and turned on some fans in the windows to exhaust out the fumes, and wore a mask (3m respirator).

Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces.  https://www.youtube.com/watch?v=ggLAUsiuI_o&feature=youtu.be

The product is an acrylic coating, which is packed conveniently for ease of use. As it is also in one-gallon size, you can rely on its supreme area coverage reaching up to 125 square feet. The Dicor rubber roof coating is also very easy to apply. When shopping around for a roof coating, we believe it pays off to find an easy to apply product for fast results. It is one of the best qualities of the RV roof coating that makes it a top pick in the category.


Spray polyurethane foam, or SPF, is the main type of 2-part, closed-cell spray foam used by insulation contractors. Large-scale insulation jobs require special equipment as well as safety gear to protect the installer from chemical fumes during installation. When the foam cures and hardens just several minutes after application, it's completely safe for as long as it stays in place.


Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.).
Sta-Kool 800 15-year White Elastomeric Roof Coating is Sta-Kool 800 15-year White Elastomeric Roof Coating is a high quality very flexible white acrylic latex roof coating. Coverage is 50-75 sq. ft. per gallon per coat. Two coatings are recommended. This performance product resists cracking and peeling while offering tremendous durability. This long lasting formula forms and excellent highly ...  More + Product Details Close 

Spray Foam Professionals


Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.

I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response.  https://m.youtube.com/watch?v=ggLAUsiuI_o&feature=youtube_gdata
When it comes to weatherproofing your RV roof, the Flex Seal liquid roof is one of those we’re proud to recommend because it can be applied in all temperatures. It can also protect your camper roof from even the harshest weathers, including rain, snow and wind. With it, you can keep your roof protected from changing temperatures, eventually prolonging its lifespan.
We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend?
While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, ocSPF is not a vapour barrier. When installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications.

How Much Better Is Spray Foam Insulation


It should be noted that your RV roof will be exposed to rain, freezing, and thawing that will eventually cause cracks. By using a high-quality sealant, it is possible for you to seal all cracks in the roof permanently. The result is cool camping within your RVs. The use of the sealant will also prevent you from facing expensive repairs in the future.

During colder months, 2 component foam is very sensitive to temperature variances. Per product instructions, both tank temperatures need to be above 70°F (21°C) for at least 24 hours prior to use. All application surfaces should be clean/dry and above 60°F (16°C) prior to application. Variance outside of the recommended temperature can affect foam yield and performance.

Roof Spray Foam Insulation

×